1.1.3.4.40 DRV_METROLOGY_CONFIGURATION Struct

C

typedef struct {
    uint32_t mc;
    double freq;
    double tr;
    double rl;
    uint32_t ku;
    DRV_METROLOGY_SENSOR_TYPE st;
    DRV_METROLOGY_GAIN_TYPE gain;
} DRV_METROLOGY_CONFIGURATION;

Summary

Identifies values needed to set different metrology configurations.

Description

Field description:

  • mc. Meter Constant (amount of energy signified by one output pulse). Units: pulses/kWh (active energy), pulses/kVARh (reactive energy), or pulses/kAmp2-h (amp square)

  • freq. Mains frequency. Units: Hz.

  • tr.

    • In the case of a current transformer, this is the current transformer ratio

    • In the case of a Rogowski Coil, this is the current sensitivity (units: uV/A) at the main frequency specified in “Frequency” parameter.

  • rl.

    • In the case of current transformer, this is the resistor load or burden resistor (units: Ω).

    • In the case of shunt resistor, this is the shunt resistor value (units: uΩ)

  • ku. Voltage divider ratio.

  • st. Sensor Type. Refer to DRV_METROLOGY_SENSOR_TYPE.

  • gain. Programmable Gain Amplifier of the AFE (analog front end). Refer to DRV_METROLOGY_GAIN_TYPE.

Remarks

None.