1.3.1.2 Metering Demo Hardware Configuration
Please check the default jumper settings for PIC32CXMTSH-DB and PIC32CXMTC-DB boards, available in the PIC32CXMTSH-DB HW User Guide and the PIC32CXMTC-DB HW User Guide. Users could change the jumper settings according to their specific requirements.
The following image shows the default jumper settings used in the Metering Demo application depending on device:
Jumper | Setting | Function |
---|---|---|
ERASE | Open | Erase pin configuration |
5V | Closed | 5V current measurement |
SHDN | Open | To enable 3.3V and 5V converters despite SHDN command |
BACK-UP | Closed | 3V3_BACK-UP current measurement |
3V3 | Closed | 3.3V current measurement |
VREFP Selection | Closed | External voltage reference |
VDDOUT | Closed | VDDOUT current measurement |
Jumper | Setting | Function |
---|---|---|
ERASE | Open | Erase pin configuration |
5V | Closed | 5V current measurement |
SHDN | Open | To enable 3.3V and 5V converters despite SHDN command |
BACK-UP | Closed | 3V3_BACK-UP current measurement |
3V3 | Closed | 3.3V current measurement |
VREFP Selection | Closed | External voltage reference |
ATSENSE | Closed | ATSENSE301 |